Send a Message to Another Terminal
From CometWiki
DOS pseudo functions: Send a Message to Another Terminal
Syntax:
DOSRW(AX-value, terminal-number, number-of-bytes, format-statement-label) EXCP=statement-label
Entry:
AX-value = "@FFFF@" . terminal-number = terminal where the message is to be sent . number-of-bytes = number of characters to be written to another terminal . format-statement-label = format statement containing the message to be written to the other terminal (may be a constant or variable)
Return:
If the write function is successful, the message contained in the format statement will be sent to the terminal specified.
If an exception occurs, byte 2 of the AX field will contain the DOS error code (in hex).
Discussion:
The DOSRW function can be used to send a message to another terminal on the Comet system. The message to be sent is contained in an Internet Basic format statement. The message may be a string constant or a string variable.
This function requires that the AX-value be set to "@FFFF@".
The second parameter in this function call is the terminal number of the terminal receiving the message. This may be a string constant or variable in the standard Comet form (for example, T00, T05, T12). To send a message to all terminals, this string should be "ALL".
The third parameter contains the number of bytes to be written to the receiving terminal. This must be a constant value hard-coded into the function call (i.e., it may not be a variable).
The fourth parameter, the format-statement-label, is the label of a FORMAT statement containing the appropriate control codes to place the message at the desired location on the receiving terminal. For example, to display a message on the bottom line (i.e., the message line), you should include the hex control "@0E07@" at the beginning of the format statement.
Example:
! S SMESSAGE,DSK ! O MESSAGE,DSK ! L T00,E ! R QMONITOR ! !========== SEND MESSAGE TO ANOTHER TERMINAL ================== ! LENGTH 2 & LOCAL AX$ ! Define AX register LENGTH 3 & LOCAL TERMINAL$ ! Define terminal number LENGTH 60 & LOCAL DATALINE$ ! Define message variable ! 100 FORMAT (ET) ! Screen format ! MESSAGE: FORMAT "@0E07@";_ ! Write to the control line (RB);(SF);_ ! Ring bell/set foreground DATALINE$ ! Display the message ! CLEAR ! Initialize all variables PRINT (0,100) ! Set typewriter mode ! PRINT (0) "ENTER TERMINAL NUMBER:" ! Display prompt INPUT (0) TERMINAL$ ! Enter terminal number IF TERMINAL$ = "" THEN RUN "QMONITOR" ! If null, then stop ! PRINT (0) "ENTER MESSAGE:" ! Display prompt INPUT (0) DATALINE$ ! Enter message to be sent IF DATALINE$ = "" THEN RUN "QMONITOR" ! If null, then stop ! AX$ = "@FFFF@" ! Set AX to "SEND MESSAGE" ! DOSRW(AX$,TERMINAL$,60,MESSAGE) EXCP=EXCEPTION ! Send message ! PRINT (0) "MESSAGE SENT TO ";TERMINAL$ INPUT (0) "" RUN "QMONITOR" ! EXCEPTION: ! Exception routine PRINT (0) "MESSAGE NOT SENT." INPUT (0) "" RUN "QMONITOR" END
Also see Send a Message to All Terminals
DOS pseudo functions